Nā hiʻohiʻona
E hoʻolalelale i kāu ʻikepili
E ʻike i ka hana ʻoi aku ka maikaʻi o DM Series a hōʻemi i ka latency mālama a hiki i 50% me NVMe ma luna o FC. E pale i kāu hoʻopukapuka kālā ma ka hoʻonui ʻana i ka wikiwiki o ka mālama ʻana ma o ka hoʻonui ʻana a me ka hoʻohui ʻana i nā mea hoʻoponopono hou aʻe i ka ulu ʻana o kāu mau pono. Kūpono ʻo DM Series no nā haʻahaʻa hana koʻikoʻi e like me ka waihona, VDI, a me ka virtualization.
Me nā ʻōnaehana uila holoʻokoʻa DM Series e:
• E kiʻi i ka 5M IOPS i hoʻokahi hui
• Kākoʻo i 2x mau haʻahaʻa hana a ʻoki i nā manawa pane noi
• Hoʻohana i ka ʻenehana Ethernet e hōʻemi i ka latency a me ka TCO haʻahaʻa me NVMe ma luna o TCP
• E hōʻoia i ka wā e hiki mai ana a e hoʻokē ʻai i kāu ʻōnaehana me ka mana NVMe hope-to-end
E hoʻonui i kāu ʻikepili
E hoʻololi me kāu hana, hiki, a i ʻole ke ao pono:
• Hoʻohui hoʻolālā no ka lawelawe ʻana i nā haʻahaʻa hana NAS a me SAN, hoʻokahi hoʻokele hoʻokele, a me ka 3:1 ʻikepili optimization no ka hōʻemi TCO.
• ʻO ka hoʻopaʻa ʻana i ke ao holoʻokoʻa a me ka hana hou ʻana e hiki ai i kahi kaiapuni multi-cloud ke streamline i ka pale ʻikepili, palekana, pono.
• E hoʻonui i waho me ka hoʻoikaika iki; hoʻopili maʻalahi i kēlā me kēia DM Series no ka ulu agile.
• Hoʻopau ka hui ʻana i ka ʻikepili i ka neʻe ʻana o ka ʻikepili; hoʻohui i nā hanauna o nā mea mālama mālama a hoʻoneʻe i ka ʻikepili mai kahi mea hoʻokele a i kekahi me ka ʻole o ka downtime.
E pale i kāu ʻikepili
ʻO ka palekana ʻikepili a me ka maluhia o ka noʻonoʻo kahi pahuhopu nui no kēlā me kēia hui. Hāʻawi ʻo DM Series all-flash system i ka ʻoihana alakaʻi i ka palekana ʻikepili i:
• Pale i ka ransomware me ka ʻike mua a me ka hoʻihoʻi hou ʻana, ma muli o ke aʻo ʻana i ka mīkini.
• Mālama i kāu ʻikepili mai nā pōʻino i manaʻo ʻole ʻia me ka hoʻohana ʻana i ka Asynchronous and Synchronous Replication.
• Hāʻawi i ka palekana ʻikepili pilikia ʻole me ka lako polokalamu hoʻopunipuni ʻikepili ma luna. E hōʻoia i ka palekana o kāu ʻikepili me ka ʻole e noʻonoʻo pono.
• E hōʻoia i ka hoʻomau ʻana o ka ʻoihana me ka nele i ka ʻikepili i ka hihia o ka pōʻino i manaʻo ʻole ʻia me SnapMirror Business Continuity a i ʻole MetroCluster.
Hōʻike ʻenehana
NAS Scale-out: 12 Kiʻekiʻe Loaʻa paʻa
Nā SSD kiʻekiʻe loa | 5760 (576 NVMe + 5184 SAS) |
---|---|
Kiʻekiʻe Raw Capacity: All Flash | 88PB* / 78.15PiB* * SAS+NVMe SSD hoʻonui |
Ka mana kūpono (ma muli o 3:1) | 264PB / 234.45PiB |
Hoʻomanaʻo kiʻekiʻe | 3072GB |
SAN Scale-out: 6 Kiʻekiʻe Loaʻa paʻa
Nā SSD kiʻekiʻe loa | 2880 (288 NVMe + 2592 SAS) |
---|---|
Kiʻekiʻe Raw Capacity | 44PB / 39.08PiB |
Ka mana kūpono | 132PB / 117.24PiB |
Hoʻomanaʻo kiʻekiʻe | 1536GB |
Hui Pūʻulu | 2x 100GbE |
Per High Availability Array Specifications: Active-Active Controller
Nā SSD kiʻekiʻe loa | 480 (48 NVMe + 432 SAS) |
---|---|
Kiʻekiʻe Makahiki: All-Flash | 7.37PB / 6.55PiB |
Ka mana kūpono | 22.11PB / 19.65PiB |
Mea Mana Puka Puka | 4U chassis me ʻelua mau mea hoʻokele High Availability |
Hoʻomanaʻo | 256GB |
NVRAM | 32GB |
Nā Kau Hoʻonui PCIe (kiʻekiʻe loa) | 10 |
Nā Awa Target FC (32Gb autoranging, maximum) | 24 |
Nā Awa Target FC (16Gb autoranging, maximum) | 8 |
Nā Awa 25GbE | 20 |
Nā Awa 10GbE (kiʻekiʻe loa) | 32 |
100GbE awa (40GbE autoranging) | 12 |
10GbE BASE-T Puka (1GbE autoranging) (kiʻekiʻe) | 16 |
12Gb / 6Gb SAS nā awa (kiʻekiʻe) | 24 |
Hui Pūʻulu | 2x 100GbE |
Kākoʻo ʻia ka Pūnaewele mālama | FC, iSCSI, NFS, pNFS, SMB, NVMe/FC, S3 |
Pūnaehana polokalamu | 9.7 a i ʻole ma hope |
Nā Papa a me Media | DM240N, DM240S |
Kākoʻo ʻia nā OSes Host/Client | Microsoft Windows, Linux, VMware ESXi |
ʻO DM Series ALL-Flash Software | ʻO nā pūʻolo polokalamu polokalamu DM Series kahi pūʻulu o nā huahana e hāʻawi i ka hoʻokele ʻikepili alakaʻi, ka mālama pono ʻana, ka pale ʻana i ka ʻikepili, ka hana kiʻekiʻe, a me nā mana kiʻekiʻe e like me ka cloning koke, replication data, application-aware backup and recovery, a me ka mālama ʻana i ka ʻikepili. |